Fig 9-11
Example of air venting device (V60D0343)
9.3.9
Expansion tank (4T05)
The expansion tank compensates for thermal expansion of the coolant, serves for venting of
the circuits and provides a sufficient static pressure for the circulating pumps.
Design data:
70 - 150 kPa (0.7...1.5 bar)
Pressure from the expansion tank at pump inlet
min. 10% of the total system volume
Volume
NOTE
The maximum pressure at the engine must not be exceeded in case an electrically
driven pump is installed significantly higher than the engine.
Concerning the water volume in the engine, see chapter Technical data.