240 Appendix
WAGO I/O SYSTEM 750 XTR
750-333/040-000 FC PROFIBUS G2 12MBd XTR
Manual
Version 1.4.0
Table 194: Data Blocks of the Complex I/O Modules with 8 Signal Channels
Index
Data object (s)
Service primitives / Data length
0x7B / 27
Table 3, Data content of register
0 - 63
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)
MSAC1/2_Write / {2, 4, 6, … 128 Byte}
2)
0x7C / 28
Diagnostic data channel 3
MSAC1/2_Read / 2 Byte
0x7D / 29
Process input data channel 3
MSAC1/2_Read / n
3
Byte
0x7E / 30
Process output data channel 3
MSAC1/2_Read / n
3
Byte,
MSAC1/2_Write / n
3
Byte
0x7F / 127
General parameter data
(parameter channel)
MSAC1/2_Read / n Byte,
MSAC1/2_Write / n Byte
0x80 / 0
Table 4, Data content of register
0 -
{0, 1, 2, … 63}
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)
0x81 / 1
Table 4, Data content of register
1 -
{1, 2, 3, … 63}
MSAC1/2_Read / {2, 4, 6, … 126 Byte}
1)
…
…
…
0x9A / 26
Table 4, Data content of register
26 -
{27, 28, 29, … 63}
MSAC1/2_Read / {2, 4, 6, … 76 Byte}
1)
0x9B / 27
Table 4, Data content of register
0 - 63
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)
MSAC1/2_Write / {2, 4, 6, … 128 Byte}
2)
0x9C / 28
Diagnostic data channel 4
MSAC1/2_Read / 2 Byte
0x9D / 29
Process input data channel 4
MSAC1/2_Read / n
3
Byte
0x9E / 30
Process output data channel 4
MSAC1/2_Read / n
3
Byte,
MSAC1/2_Write / n
3
Byte
0x9F / 31
Reserved for extensions
-
0xA0 / 0
Table 5, Data content of register
0 -
{0, 1, 2, … 63}
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)
0xA1 / 1
Table 5, Data content of register
1 -
{1, 2, 3, … 63}
MSAC1/2_Read / {2, 4, 6, … 126 Byte}
1)
…
…
…
0xBA / 26
Table 5, Data content of register
26 -
{27, 28, 29, … 63}
MSAC1/2_Read / {2, 4, 6, … 76 Byte}
1)
0xBB / 27
Table 5, Data content of register
0 - 63
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)
MSAC1/2_Write / {2, 4, 6, … 128 Byte}
2)
0xBC / 28
Diagnostic data channel 5
MSAC1/2_Write / 2 Byte
0xBD / 29
Process input data channel 5
MSAC1/2_Read / n
3
Byte
0xBE / 30
Process output data channel 5
MSAC1/2_Read / n
3
Byte,
MSAC1/2_Write / n
3
Byte
0xBF / 31
Reserved for extensions
-
0xC0 / 0
Table 6, Data content of register
0 -
{0, 1, 2, … 63}
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)
0xC1 / 1
Table 6, Data content of register
1 -
{1, 2, 3, … 63}
MSAC1/2_Read / {2, 4, 6, … 126 Byte}
1)
…
…
…
0xDA / 26
Table 6, Data content of register
26 -
{27, 28, 29, … 63}
MSAC1/2_Read / {2, 4, 6, … 76 Byte}
1)
0xDB / 27
Table 6, Data content of register
0 - 63
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)
MSAC1/2_Write / {2, 4, 6, … 128 Byte}
2)
0xDC / 28
Diagnostic data channel 6
MSAC1/2_Read / 2 Byte
0xDD / 29
Process input data channel 6
MSAC1/2_Read / n
3
Byte
0xDE / 30
Process output data channel 6
MSAC1/2_Read / n
3
Byte,
MSAC1/2_Write / n
3
Byte
0xDF / 31
Individual parameter data
(iPar server index)
MSAC1/2_Read / n Byte,
MSAC1/2_Write / n Byte
0xE0 / 0
Table 7, Data content of register
0 -
{0, 1, 2, … 63}
MSAC1/2_Read / {2, 4, 6, … 128 Byte}
1)