WAGO I/O SYSTEM 750 XTR
Appendix 165
750-333/040-000 FC PROFIBUS G2 12MBd XTR
Manual
Version 1.4.0
Table 105: Analog Output Modules
– Process Image Information
PBDP module type
PI
Offset
[Byte]
Bit/byte allocation
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
2AO(_PAR)
O
0
Output data
Channel 0, HB
4
(LB
5
)
1
Output data
Channel 0, LB
4
(HB
5
)
2
Output data
Channel 1, HB
4
(LB
5
)
3
Output data
Channel 1, LB
4
(HB
5
)
2AO_RA(_PAR)
I
0
PD
RA
F
0
Status 0 / Register RES
Channel 0 / Table 0
1
Register data RD
Table 0, HB
4
(LB
5
)
2
Register data RD
Table 0, LB
4
(HB
5
)
3
PD
RA
F
0
Status 1 / Register RES
Channel 1 / Table 0
4
Register data RD
Table 1, HB
4
(LB
5
)
5
Register data RD
Table 1, LB
4
(HB
5
)
O
0
PD
RA
0
RW
Control 0 / Register REQ
Channel 0 / Table 0
1
Output data
Channel 0, HB
4
(LB
5
)
Register data WR
Table 0, HB
4
(LB
5
)
2
Output data
Channel 0, LB
4
(HB
5
)
Register data WR
Table 0, LB
4
(HB
5
)
3
PD
RA
0
RW
Control 1 / Register REQ
Channel 1 / Table 1
4
Output data
Channel 1, HB
4
(LB
5
)
Register data WR
Table 1, HB
4
(LB
5
)
5
Output data
Channel 1, LB
4
(HB
5
)
Register data WR
Table 1, LB
4
(HB
5
)
4AO
O
0
Output data
Channel 0, HB
4
(LB
5
)
1
Output data
Channel 0, LB
4
(HB
5
)
2
Output data
Channel 1, HB
4
(LB
5
)
3
Output data
Channel 1, LB
4
(HB
5
)
4
Output data
Channel 2, HB
4
(LB
5
)
5
Output data
Channel 2, LB
4
(HB
5
)
6
Output data
Channel 3, HB
4
(LB
5
)
7
Output data
Channel 3, LB
4
(HB
5
)