Page 56 of 58
POS-123-*-2030
8.9.5
SSI:RES (Signal resolution)
Command
Parameters
Unit
Group
SSI:RES
x
x= 100… 10000
0,01 µm
SSI
The sensor signal resolution
23
is defined with this parameter. Data is entered with the resolution of 10 nm
(nanometer or 0,01µm). This means that if the sensor has 1 µm resolution the value 100 must be specified.
This also makes it possible to scale rotational sensors.
The appropriate data is to be found in the sensor data sheet.
8.9.6
SSI:BITS (Number of data bits)
Command
Parameters
Unit
Group
SSI:BITS x
x= 8… 31
bit
SSI
The number of data bits is entered with this parameter.
The appropriate data is to be found in the sensor data sheet.
8.9.7
SSI:CODE (Signal coding)
Command
Parameters
Unit
Group
SSI:CODE x
x= GRAY|BIN
-
SSI
The data coding is entered with this parameter.
The appropriate data is to be found in the sensor data sheet.
8.9.8
SSI:ERRBIT (Position of the
“out of range” bit)
Command
Parameter
Unit
Group
SSI:ERRBIT X
x= 8… 31
bits
SSI
The position of the error bit will be defined by this parameter.
The appropriate data is to be found in the sensor data sheet.
In case of no error bit, the default value is 0.
23
The internal resolution of the module is 1 µm. This is also the lowest resolution of the sensor.