Page 53 of 58
POS-123-*-2030
8.5 Typical wiring
8.6 Technical data
Supply voltage
Current requirement
Fuse protection
[VDC]
[mA]
[A]
24... 30
350
1 (medium time lag)
SSI interface
-
RS-422 specification, 120 kBaud
22
Analoge output
[V]
0… 10 (10 mA max load)
Housing
Snap-on module EN 50022
Polyamide PA 6.6
Flammability class V0 (UL94)
Temperature range
[°C]
-
20… 60
Storages temperature
[°C]
-
20… 70
Weight
[kg]
0,250 (incl. standard module)
Connections
2 x 4-pole terminal blocks
CAUTION
: For supply voltage and current requirement the technical data of the sensor have to
be considered.
22
The relative low baud rate is used to get a very stable communication. The cycle time of 1 ms of the position controller is
not affected.
PE
Kl
em
m
e
PE
Kl
em
m
e
Power supply
24V
0V
24
23
22
21
32
31
30
29
28
27
26
25
20
19
18
17
CLK-
CLK+
DATA-
DATA+
GND
+24 V DC
SSI / SSD
Interface
+/- 10 V
control valve
8
7
6
5
16
15
14
13
12
11
10
9
4
3
2
1