7.7 Parameter overview of the power station
Command
Default
Unit
Description
V -
Type of the monitor output signal
+ -
Output polarity
1000 mA
Output current range
121 Hz
Dither frequency
500 0,01 %
Dither amplitude
2604 Hz
PWM frequency
ON -
Automatical calculation of the PPWM and IPWM
parameter
7
40
-
-
Current control loop PI control dynamics
The standard parameterization has been used with a large number of proportional vales from various
manufacturers. This parameterization has proved to be good as long as no special demands concerning the
application have to be fulfilled.
7.8 Parameter description of the power stage
7.8.1
SIGNAL:M (Type of the monitor output signal)
Command
Parameter
Unit
Group
SIGNAL:M x
x= U0-10|I4-20
-
EXP
This command is used to define the output signal (voltage = U0-10 or current = I4-20).
7.8.2
SIGNAL:U (Polarity of the output signal)
Command
Parameters
Unit
Group
SIGNAL:U x
x= +|-
-
STD
The output polarity is set by this parameter.