Page 43 of 58
POS-123-*-2030
7.3 Inputs and outputs
Connection
Signal description
PIN 22 +
PIN 24 -
Power supply
: 10… 30 VDC:
For safety-related applications, the output stage
can be deactivated thanks to the separate power supply inputs.
PIN 17 + 19
Solenoid current output A
PIN 18 + 20
Solenoid current output B
Connection
Signals modified from the standard (A and I version)
PIN 15
0… 10 V / 4… 20 mA output with the scaled position demand value
PIN 16
0
… 10 V / 4… 20 mA
17
output with the scaled position actual value
7.4 Circuit diagram
ATTENTION
, SENS = AUTO is not recommended is case of correct failure monitoring
18
.
17
The 4… 20 mA at PIN 16 will be available in 3Q /2015 or on request.
18
In case of deactivated solenoid (solenoid B is active and solenoid A is not active) a failure a solenoid A cannot be recog-
nized always.
Power supply
22
24
24 V
0 V
17
19
10..30V
0V
***-***P
Power output stage
18
20
Internal MCU
interface
Solenoid A
Solenoid B
ia
ib
fo
r
e
xp
a
m
p
le
:
H
A
W
E
v
a
lv
e
s
17
19
20
18