7 ADDITIONAL INFORMATION: Power output stage
7.1 General function
The power output stages have been developed for controlling proportional valves without spool position
feedback. The output stage is controlled by the microcontroller on the basic module by means of pulse width
modulated signals, and the current is continuously controlled. The cycle time for the controller is 0,125 ms.
The output stage can be ideally adjusted to dynamic requirements via internal parameters.
Valve technology: Proportional valves manufactured by REXROTH, BOSCH, DENISON, EATON, PARKER,
FLUID TEAM, ATOS and others.
Features
Two power output stages with maximum output range of 0.5 A to 2,6 A
Hardware short-circuit protection with 3 µs response time
Adjustable PWM frequency, dither frequency and dither amplitude
High current signal resolution
No additional delay times between the control function and the power stage
Separate power supply for safety-relevant applications
Integrated into the standard controller, no additional wiring necessary
Optimum price/performance ratio