Page 44 of 58
POS-123-*-2030
7.5 Typical wiring
CAUTION:
The solenoid cables should be screened due to electro-magnetic emissions.
CAUTION:
plugs with
free-wheeling diodes and LED indicators cannot be used with current-
controlled power outputs. They interfere with the current control and can destroy the output
stage.
7.6 Technical data
Supply voltage
Power consumption max.
Fuse protection
[VDC]
[W]
[A]
10... 30
60 (depending on the solenoid)
3 (medium time lag)
PWM output
PWM frequency
[A]
[Hz]
0,5, to 2,6 (step less selectable); broken
wire and short circuit monitored
61
… 2604
Sample time solenoid current
control
[ms]
0,125
Temperature range
[°C]
-
20… 60
Housing
Snap-on module EN 50022
Polyamide PA 6.6
Flammability class V0 (UL94)
Weight
[kg]
0,250 (incl. standard module)
Connections
3 x 4-pole terminal blocks
PE
K
le
m
me
PE
K
le
m
me
Power supply
24V
0V
8
7
6
5
16
15
14
13
12
11
10
9
4
3
2
1
24
23
22
21
32
31
30
29
28
27
26
25
20
19
18
17
0V
Solenoid A
Solenoid B