Display fault
code
System char-
acteristics
Cause
Measures
bd
Control mode
without remote
control
Communication fault
–
Vitotrol remote control,
heating circuit with mixer
M2
bE
Control mode
Vitotrol remote control in-
correctly encoded
Check remote
control DIP switch
setting (see
page 97)
bF
Control mode
Incorrect LON communi-
cation module
Replace the LON
communication
module
C2
Control mode
Communication fault
–
solar control unit
Check connec-
tions and coding
address "54"
C5
Control mode,
max. pump
speed
Communication fault
–
in-
ternal variable speed
pump
Check coding ad-
dress "30" set-
tings; check the
heating circuit
pump DIP switch
settings
C6
Control mode,
max. pump
speed
Communication fault
–
variable speed circulation
pump, heating circuit with
mixer M2
Check coding ad-
dress "E5" set-
tings; check the
heating circuit
pump DIP switch
settings
C7
Control mode,
max. pump
speed
Communication fault
–
variable speed circulation
pump, heating circuit A1
Check coding ad-
dress "E5" set-
tings; check the
heating circuit
pump DIP switch
settings
Cd
Control mode
Communication fault
Vitocom 100 (KM BUS)
Check the
Vitocom 100 and
connections
CE
Control mode
Communication fault
–
ext. extension
Check connec-
tions and coding
address "2E" set-
tings
Fault codes
(cont.)
71
Troubleshooting
5692
536
GB
Summary of Contents for Vitoplus 300
Page 103: ...Parts lists cont 103 Parts lists 5692 536 GB ...
Page 104: ...Parts lists cont 104 Parts lists 5692 536 GB ...
Page 105: ...Parts lists cont 105 Parts lists 5692 536 GB ...
Page 106: ...Parts lists cont 106 Parts lists 5692 536 GB ...
Page 107: ...Parts lists cont 107 Parts lists 5692 536 GB ...
Page 119: ...119 5692 536 GB ...