Coding in the delivered condition
Possible change
24:0
No "Maintenance" dis-
play
24:1
"Maintenance" display
(the address is automati-
cally set and must be
manually reset after a
service has been carried
out)
26:0.
Burner fuel consump-
tion (stage 1); no count
if "26:0" is encoded
26:1
26:255
Entering 0.1 to 25.5;
1 step
≙
0.1 litres or gal-
lons/hour
29:0
Burner fuel consump-
tion (stage 1 and 2); no
count if "29:0" is en-
coded
29:1
to
29:255
Entering 0.1 to 25.5; 1
step
≙
0.1 litres or gal-
lons/hour
2E:0
Without external exten-
sion
2E:1
With external extension
(automatic adjustment on
connection)
2F:0
Venting program/filling
program disabled
2F:1
Venting program enabled
2F:2
Filling program enabled
30:1
Internal variable speed
circulation pump (auto-
matic adjustment)
30:0
Internal circulation pump
without variable speed
(e.g. temporarily for ser-
vice)
31:65
Set speed of internal
circulation pump when
operated as boiler cir-
cuit pump 65%, de-
faulted by boiler coding
card
31:0
to
31:100
Set speed adjustable
from 0 to 100%
32:0
Influencing signal "Ex-
ternal blocking" on cir-
culation pumps: All
pumps in control func-
tion
32:1
to
32:15
Influencing signal "Exter-
nal blocking" on circula-
tion pumps: see the
following table
Code 2
(cont.)
44
Coding
5692
536
GB
Summary of Contents for Vitoplus 300
Page 103: ...Parts lists cont 103 Parts lists 5692 536 GB ...
Page 104: ...Parts lists cont 104 Parts lists 5692 536 GB ...
Page 105: ...Parts lists cont 105 Parts lists 5692 536 GB ...
Page 106: ...Parts lists cont 106 Parts lists 5692 536 GB ...
Page 107: ...Parts lists cont 107 Parts lists 5692 536 GB ...
Page 119: ...119 5692 536 GB ...