Coding
Internal
circula-
tion pump
Heating cir-
cuit pump
Heating cir-
cuit without
mixer
Heating circuit
pump
Heating circuit
with mixer
Cylinder primary
pump
0
Control
funct.
Control funct. Control funct.
Control funct.
1
Control
funct.
Control funct. Control funct.
OFF
2
Control
funct.
Control funct. OFF
Control funct.
3
Control
funct.
Control funct. OFF
OFF
4
Control
funct.
OFF
Control funct.
Control funct.
5
Control
funct.
OFF
Control funct.
OFF
6
Control
funct.
OFF
OFF
Control funct.
7
Control
funct.
OFF
OFF
OFF
8
OFF
Control funct. Control funct.
Control funct.
9
OFF
Control funct. Control funct.
OFF
10
OFF
Control funct. OFF
Control funct.
11
OFF
Control funct. OFF
OFF
12
OFF
OFF
Control funct.
Control funct.
13
OFF
OFF
Control funct.
OFF
14
OFF
OFF
OFF
Control funct.
15
OFF
OFF
OFF
OFF
Coding in the delivered condition
Possible change
Boiler/burner
34:0
Influence of the signal
"External demand" on
the circulation pumps:
All pumps in control
function
34:1
to
34:23
Influence of the signal
"External demand" on the
circulation pumps: see
the following table
Code 2
(cont.)
45
Coding
5692
536
GB
Summary of Contents for Vitoplus 300
Page 103: ...Parts lists cont 103 Parts lists 5692 536 GB ...
Page 104: ...Parts lists cont 104 Parts lists 5692 536 GB ...
Page 105: ...Parts lists cont 105 Parts lists 5692 536 GB ...
Page 106: ...Parts lists cont 106 Parts lists 5692 536 GB ...
Page 107: ...Parts lists cont 107 Parts lists 5692 536 GB ...
Page 119: ...119 5692 536 GB ...