Coding in the delivered condition
Possible change
F2:8
Time limit for party
mode 8 hours or exter-
nal operating mode
changeover via key
*
1
F2:0
No time limit for party
mode
F2:1
to
F2:12
Time limit adjustable from
1 to 12 h
F5:12
Run-on time of the inter-
nal circulation pump in
heating mode
F5:0
No run-on time of the in-
ternal circulation pump
F5:1
to
F5:20
Run-on time of the inter-
nal circulation pump ad-
justable from 1 to 20 min
Burner
F8:
–
5
For the operation in re-
duced room tempera-
ture mode, the set room
temperature will be
raised (up to the tem-
perature limit set by
coding address F9) to a
value subject to the out-
side temperature, if the
outside temperature
falls below -5 °C, see
example on page 95.
Observe the setting of
coding address A3.
F8:+10
to
F8:
–
60
Limit for raising the tem-
perature in reduced
mode adjustable from
+10 to -60 °C
F8:
–
61
Function disabled
F9:
–
14
Below an outside tem-
perature of -14 °C, the
set room temperature
will be raised to the
value selected as set
room temperature, if the
system operates with
the standard room tem-
perature, see the exam-
ple on page 95
F9:+10
to
F9:
–
60
Limit for raising the set
room temperature to the
value selected for stan-
dard mode adjustable
from +10 to -60 °C
Code 2
(cont.)
59
Coding
5692
536
GB
*1
Party mode ends
automatically
in heating program "
rw
" when the system changes
over to operation with standard room temperature.
Summary of Contents for Vitoplus 300
Page 103: ...Parts lists cont 103 Parts lists 5692 536 GB ...
Page 104: ...Parts lists cont 104 Parts lists 5692 536 GB ...
Page 105: ...Parts lists cont 105 Parts lists 5692 536 GB ...
Page 106: ...Parts lists cont 106 Parts lists 5692 536 GB ...
Page 107: ...Parts lists cont 107 Parts lists 5692 536 GB ...
Page 119: ...119 5692 536 GB ...