Rated voltage:
230 V ~
Rated frequency:
50 Hz
Rated current :
6.0 A
Safety class:
I
Protection:
IP 20
Permissible ambient temperatures
&
during operation:
0 to +40 °C
&
during storage
and transport:
-20 to +65 °C
Control thermostat
and temperature
controller settings:
75 °C
Temperature limiter
setting:
100 °C
Line fuse (mains):
max. 16 A
Power consumption
&
Circulation pump:
max. 115 W
&
Burner:
max. 60 W
&
Control unit:
max. 10 W
Oil fired condensing boiler, type B
23
, C
33x
, C
53x
, C
63x
Rated output
kW
12.9/19.3
16.1/23.5
Burner stage
Stage 1
Stage 2
Stage 1
Stage 2
Rated output
at burner stage
kW
12.9
19.3
16.1
23.5
Power consumption
with circulation pump
W
205
255
218
280
Motor speed
Oil pump drive
r.p.m.
2880
2880
Capacity
Oil pump
l/h
45
45
Burner version
Two-stage
Two-stage
Product ID
_
-0645 BM 112.2
Product characteristics (to EnEV [Germany])
Rated output range
kW
12.9/19.3
16.1/23.5
Efficiency
η
at
&
100 % of rated output
%
96.1
96.0
&
30% of rated output
%
103.7
103.5
Standby loss
q
B,70
*
1
%
1.27
1.10
Power consumption
*
1
at
&
100% of rated output
W
180
198
&
30% of rated output
W
60
66
Specification
114
Specification
5692
536
GB
*1
Max. limit to EnEV [Germany]
Summary of Contents for Vitoplus 300
Page 103: ...Parts lists cont 103 Parts lists 5692 536 GB ...
Page 104: ...Parts lists cont 104 Parts lists 5692 536 GB ...
Page 105: ...Parts lists cont 105 Parts lists 5692 536 GB ...
Page 106: ...Parts lists cont 106 Parts lists 5692 536 GB ...
Page 107: ...Parts lists cont 107 Parts lists 5692 536 GB ...
Page 119: ...119 5692 536 GB ...