background image

Part # 4525958 (10/28/08)

Page 1

Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent 
using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been 
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation 
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, 
or which has been modified or repaired using unauthorized parts or by unauthorized service agents . 
For a list of authorized service agents, please refer to the Garland web site at http://www .garland-group .com . 

The information contained herein, (including design and parts specifications), may be superseded and is subject 

to change without notice .

GARLAND COMMERCIAL INDUSTRIES

185 East South Street

Freeland, Pennsylvania 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES, LTD .

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD .

5E Langley Business Centre 

Station Road, Langley SL3 8DS Great Britain

Phone: 01753 485900

Fax: 01753 4859011

Part # 4525958 (10/28/08)

© 2008 Garland Commercial Industries, Inc .

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE 

OR OTHER FLAMMABLE VAPORS OR 

LIQUIDS IN THE VICINITY OF 

THIS OR ANY OTHER

APPLIANCE

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, 

ALTERATION, SERVICE OR MAINTENANCE 

CAN CAUSE PROPERTY DAMAGE, INJURY, 

OR DEATH. READ THE INSTALLATION, 

OPERATING AND MAINTENANCE 

INSTRUCTIONS THOROUGHLY 

BEFORE INSTALLING OR 

SERVICING THIS EQUIPMENT

PLEASE READ ALL SECTIONS OF THIS MANUAL 

AND RETAIN FOR FUTURE REFERENCE .

THIS PRODUCT HAS BEEN CERTIFIED AS 

COMMERCIAL COOKING EQUIPMENT AND 

MUST BE INSTALLED BY PROFESSIONAL 

PERSONNEL AS SPECIFIED . 

IN THE COMMONWEALTH OF MASSACHUSETTS 

THIS PRODUCT MUST BE INSTALLED BY A 

LICENSED PLUMBER OR GAS FITTER . 

For Your Safety:

Post in a prominent location, instructions to be 

followed in the event the user smells gas . This 

information shall be obtained by consulting 

your local gas supplier .

INSTALLATION AND 

OPERATION MANUAL

GARLAND G-BRL & GF-BRL 

SERIES BROILERS

Includes Models: G18-BRL, G24-BRL, G30-BRL, 

G36-BRL, G48-BRL, GF18-BRL,GF24-BRL,GF30-BRL 

and  GF36-BRL

Only GF Series Broilers are CE Approved

Summary of Contents for G18-BRL

Page 1: ...624 5669 Enodis UK LTD 5E Langley Business Centre Station Road Langley SL3 8DS Great Britain Phone 01753 485900 Fax 01753 4859011 Part 4525958 10 28 08 2008 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN C...

Page 2: ...ould expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of california to cause cancer Operation of this product could expose you to carbon monoxide if not adjusted properly Inhalation of carbon monoxide is known to the state of california to cause birth defects or other reproductive harm Keep appliance a...

Page 3: ...TALLATION 7 Rating Plate Location 7 Statutory Regulations 7 Australia Specific Clause 7 Gas Supply 8 Gas Connections 8 Counter Line Installations 8 Location 8 Sanitary Counter Top Seal 8 Leg Installation 9 Assembly of Counter Stands 9 Installation for Units Equipped with Casters 10 Cabinet Bases 10 Assembly Of Broiler 10 Ventilation 10 OPERATION 11 Grid Rack Seasoning Instructions 11 Lighting Inst...

Page 4: ...F18 BRL 18 457mm 25 1 8 636mm 34 1 2 876mm 190 86 21 3 45 000 13 2 GF24 BRL 24 610mm 25 1 8 636mm 34 1 2 876mm 240 109 21 4 60 000 17 6 GF30 BRL 30 762mm 25 1 8 636mm 34 1 2 876mm 290 131 29 5 5 75 000 22 GF36 BRL 36 914mm 25 1 8 636mm 34 1 2 876mm 340 154 29 5 6 90 000 26 4 NOTE Only GF series broilers with flame failure features are CE approved A REAR GAS CONNECTION 1 3 8 45mm 34 1 2 876mm 24 1 ...

Page 5: ...4 375mm 5 125mm DIMENSIONS AND SPECIFICATIONS BROILERS continued Gas Pressure North America General International Markets Operating Manifold Pressure Natural G20 4 5 wc 11 2mbar LPG G31 10 wc 24 9mbar Australian Market Operating Manifold Pressure Natural 4 wc 1 0kPa LPG 10 wc 2 49 kpa Input Per burner MJ H Injector Dia MJ H Injector Dia 15 8 1 9 mm 15 8 1 1 mm Clearances For use in non combustible...

Page 6: ...0 BRL 29 5 50 23 G36 BRL CAB Closed Cabinet 36 914mm Wide G36 BRL GF36 BRL 29 5 60 27 G48 BRL CAB Closed Cabinet 48 1219mm Wide G48 BRL 37 65 29 5 Many local codes exist and it is the responsibility of the Owner and the Installer to comply with those codes Garland reserves the right to change or improve product specifications without notification Garland products are not approved or authorized for...

Page 7: ...luding the prefix and suffix letters and numbers and the warranty serial number The rating plate affixed to the unit contains this information We suggest installation maintenance and repairs should be performed by your local authorized service agency listed in your information manual pamphlet In the event you have any questions concerning the installation use care or service of the product write o...

Page 8: ...ompletely new installation have gas lines meter size piping and piping installed and checked by a qualified gas technician H Make certain that the new piping joints and connections have been made in a clean manner and have been purged so that the piping compound chips etc will not clog pilots valves and or controls Use pipe joint sealant that is resistant to liquefied petroleum gas WARNING Check g...

Page 9: ... a spirit level and level unit by cooking grids four 4 ways across the front and back and down the sides Assembly of Counter Stands 1 Fit stand ends together see diagram 2 Secure stand together with eight 8 10 24 machine screws eight 8 1 4 lock nuts eight 8 10 24 hex nuts provided Use only front and back pieces 3 If stand exceeds a four 4 foot length see optional cross member Optional cross member...

Page 10: ...RL or 2 sets of 21 533mm 48 BRL long steel rods These rods are to be installed in the grooves on the support brackets which are atop the burners INSTALLATION continued Briquettes For best cooking results it is recommended that the correct amount of briquettes are installed in the broiler Refer to the table and drawing below for the proper arrangement of briquettes When all the briquettes have been...

Page 11: ... Models G 18 24 39 36 48 BRL 1 One pilot serves two burners and is located between those burners 2 Push red spark buttons several times to ignite pilot burners 3 Ensure pilots are lit by viewing through pilot view hole on front of unit Models GF 18 24 30 36 BRL 1 Push in the valve knob and turn counter clockwise to the ignition position 2 While holding the knob fully in depress the ignitor button ...

Page 12: ...FF at end of daily operation 7 When the grill is running never use objects such as sheet pans to cover the gill in order to hold in heat in an attempt to burn off grease or other debris Exterior Finish Cleaning Establish a regular schedule Any spills should be wiped off immediately 1 Wipe exposed clean able surface when cool with a mild detergent and hot water Stubborn residue spots may be removed...

Page 13: ...Part 4525958 10 28 08 Page 13 ...

Page 14: ...Part 4525958 10 28 08 Page 14 ...

Page 15: ...Part 4525958 10 28 08 Page 15 ...

Page 16: ......

Reviews: