I N S T A L L A T I O N D A T A S H E E T - P R O G R A M M I N G
New functionalities
To manage power failure from the mains, it is necessary to plug a
220/12V 2,2A transformer on the mains of the site to be watched
and supply with the 12 volts of the loop GND and POWER without
forgetting the two loops (in red), as shown in the diagram below.
Of course to transmit the default of the failure of the mains it is
necessary in this case to transmit the events:
AC POWER.
on a
state
ALARM / END
.
Go to the menu to modify the state of events
:
CONFIGURATION
->
CONFIGURATION MONITOR. STATION
->
ALARM CODES
->
TRANS. STATE MODIFICATION
Modify the transmission of events :
AC POWER
on the state
ALARM / END.
}
12V 2,2A
Loops
Entry 1
Power (+12V)
GND (0V)