INSTRUCTION MANUAL
for installation and operation of pellet boiler
CLASSIC 40C
7
5. Safety devices.
Fume thermocouple:
It is placed at the top part of the heat exchanger
Thermo-limiter:
To prevent overheating of the system, with manual reset. Measure the temperature of the water into
the integral boiler. When it reaches a value of 100°С, it interrupts the power to the water boiler. If the thermostat has
been activated, it must be reset manually by pressing the switch on the back of the pellet boiler (see Fig. 1., Pos. А).
Thermostat of the pellet fuel hopper:
Placed on the auger housing near the pellet fuel hopper. It interrupts feeding of
the pellets, if its temperature reaches 85°C, also interrupts the indication of the water temperature sensor and stops the
water boiler with alarm.
Thermoregulator:
Measure the temperature of the water in the integral boiler and sends information to the control
system.
Hydraulic safety valve:
Upon reaching a pressure of 3.0 bar, the system is activated to emit liquid. After discontinuation
of the emergency, the system must be added to the required pressure (1.5 bar).
Fuse:
At the main switch of the pellet boiler has built two fuses, one of whom is working and the other is a spare.
6. Electrical wiring diagram.
Diagram 1