- Vacuum the combustion chamber and all contact edges;
- Clean the glass when it is cold. If necessary, use appropriate detergent.
Never vacuum hot coals, because this may damage it!
13.2. Weekly cleaning.
-
Empty pellet fuel hopper and clean with a vacuum cleaner if the pellet boiler was not used for an extended period.
-
Clean ignition (figure 7).
13.3. Cleaning ash from the flue channels.
The cleaning is performed automatically
.
The amount of soot depends on the quality of fuel used.
Remove the 2 nuts from the cover of the smoke collector (left or right side of the pellet boiler),
remove the internal ashtray and clean it.
Fig.8
13.4. Seasonal maintenance
Seasonal maintenance (performed by the installer).
Disconnect the power supply of the pellet boiler before performing any activity!
- Clean propulsion parts and electric motors. Make sure there are no gaps;
- Clean the flue channels and chamber of fume extractor;
- Clean and check the circulation pump;
- Check sensors;
- Clean, check and remove all debris from the ignition system;
- Clean and check the electronic control system;
- Check all electrical cables;
- Clean the pellet fuel hopper and check auger to loosen the screw and the gear motor;
- Check and if needed replace the door seal;
- Make a functional test, insert a small amount of wood pellets in the hopper enough to fill auger. Light a pellet boiler for 10
minutes and shutdown.
It is recommended that the chimney have to be cleaned every three months in intensive use of the pellet boiler.
If maintenance procedures are not performed regularly, the guarantee shall be considered invalid!
13.5. Maintenance and control.
The chimney, to which is connected to the pellet boiler must be cleaned once a year. Check that if there is a regulatory
standard for this in your country. If you do not make periodic inspection and cleaning of chimney, the probability of fire is
increased many times. In such incident do the following:
- Do not extinguish with water;
- Empty the pellet fuel hopper of wood pellets;
- Contact the person who installed the pellet boiler, before starting again.
14. Possible defects and their causes.
When a problem occurs, pellet boiler automatically stops working and triggering shut down procedure. The display shows the
reason why pellet boiler has stopped working. Error messages are described below.