background image

05.2020 

 

 

INSTRUCTION MANUAL 

for installation and operation of pellet boiler

 CLASSIC 40C

 

 

 

3

 

 

 

 

1.

 

Introduction. 

We congratulate you on the excellent choice! 

 Do  not  leave  this  instruction  manual  unread.  Installation  and  operation  of  a  pellet  boiler  associated  with  various 
legal obligations, which are explained in this instruction manual. According to the laws and regulations for safe use of 
appliances of this class, the purchaser and user of the pellet boiler undertake using this instruction manual to inform 

themselves for the assembling and the right operation of the appliance. 

This  instruction  manual  is  provided  to  assist  you  and  the  team  that  will  install,  put  into  operation  and  service  pellet  boiler. 
Technicians, who will carry out the above activities to the pellet boiler, must be trained and competent. 

Pellet  boiler  is  operated  only  by  adult  persons  familiar  with  the  instruction  manual.  Pellet  boiler  is  not  intended  for  use  by 
persons with limited physical, sensory or mental abilities or lack of experience and knowledge, unless they are instructed and 
supervised in the use of the appliance by a person responsible for their safety. 

Pellet boiler is manufactured and tested in accordance with standards EN 303-5: 2012, EN 60335-1, EN 60335-2-102, EN 55014-
1, EN 61000-6-3 and meets the approved technical documentation. 

Failure to follow the instructions described in this manual can lead to damage and consequences for which the manufacturer is 
not responsible. 

2.Safety Information. 

• 

Pellet boiler must not run without water in the system and the pressure must not fall below 1 bar. If the system is used 

without water, pellet boiler can be damaged. 

• 

Pellet  boiler  is  designed  to  heat  water  through  automated  burn  in  the  combustion  chamber  of  wood  pellets  with  a 

diameter of Ø 6 mm

 class A1

 . 

• 

Warranty is voided by unauthorized use of combustible material. 

• 

The  risk  that  could  arise  from  non-compliance  of  this  instructions  manual  is  a  direct  contact  with  electric  parts 

(internal), contact with fire or hot surfaces. 

• 

Pellet boiler is equipped with safety components that guarantee automatically shut down in case of failure of any of its 

components. Safety components are activated without outside interference. 

• 

Necessary  for  the  proper  operating  of  the  pellet  boiler  is  its  proper  installation  in  accordance  with  the  following 

instructions. 

• 

Fire door should not be opened during operation of the pellet boiler. The burning process is automated and does not 

require external intervention. 

• 

It is not allowed to burn the pellet boiler if there are cracks in the glass. 

• 

Under no circumstances should not be allowed any penetration of foreign substances in the firebox or hopper. 

• 

Do not use combustible materials to clean soot in the chimney. 

• 

Turn off the pellet boiler from the grid-circuit before cleaning or servicing. 

• 

Use a vacuum cleaner to clean the combustion chamber and pellet fuel hopper only when pellet boiler is cold. 

• 

Do not use water to clean the internal parts of the pellet boiler. 

• 

ATTENTION!

 During operation of the pellet boiler it is not allowed to touch its surface especially by a child as it is hot. 

Danger of burning! 

• 

The handle of the pellet boiler warms as much as the front panel, so it must be operated with a heat-resistant glove. 

 

During operation of the pellet boiler flue pipes and fire door are hot. 

• 

Do not place flammable objects and liquids near the pellet boiler. 

• 

NEVER

 use flammable liquids to start the pellet boiler. 

• 

Do not obstruct fresh air to enter the room where the pellet boiler is installed and the holes on the pellet boiler. 

• 

Do not soak pellet boiler and do not touch electrical components with wet hands. 

• 

Do not mount any adapters to flue pipes and chimney. 

• 

To  operate  properly  and  safely,  pellet  boiler  should  be  installed  in  a  room  that  is  fire-resistant  and  equipped  with 

everything needed (electricity, air exchange, vents, water supply and drainage). 

• 

The temperature of the room where it is installed the pellet boiler must not be lower than 0˚C. 

• 

Use appropriate non-freezing additives for water in the system. 

• 

Make sure the temperature of the return water is not lower than 45˚C. 

• 

Rating label is placed on the back of the pellet boiler. 

Summary of Contents for CLASSIC 40C

Page 1: ...INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC 40C...

Page 2: ...11 2 CONTROL PANEL DESCRIPTION 13 11 2 1 MAIN USER CONTROL PANEL 13 11 2 2 TYPES OF MODES OF THE CONTROL UNIT 14 11 2 3 MAIN MENU 14 11 2 5 SERVICE TECHNICIAN SETTINGS 18 12 INSTRUCTION MANUAL 19 12...

Page 3: ...act with fire or hot surfaces Pellet boiler is equipped with safety components that guarantee automatically shut down in case of failure of any of its components Safety components are activated withou...

Page 4: ...hould not be placed back in the pellet fuel hopper 3 Technical data and dimensions Fig 1 Button with safety cover to reset the thermo limiter Main switch with integrated socket for power cable out for...

Page 5: ...construction of the pellet boiler allows mounting of the ashtray in left side or right side 1 1 1 Pellet boiler 2 Bracket 3 Screw 6 12 DIN 912 2 pcs 4 Washer 6 DIN 125 6 pcs 5 Screw 6 x 16 DIN 912 2 p...

Page 6: ...ximum draught 12 Duration of combustion at nominal heat output at reduced heat output 14 h 47 h Fuel consumption minimum maximum 2 56 8 51 Type and dimensions of fuel Wood pellets 6 mm length 25 mm cl...

Page 7: ...tat of the pellet fuel hopper Placed on the auger housing near the pellet fuel hopper It interrupts feeding of the pellets if its temperature reaches 85 C also interrupts the indication of the water t...

Page 8: ...er works with wood pellets These are cylindrical granules made of pressed wood whose combustion is controlled by an electronic control system The heat from the combustion process is given to the fluid...

Page 9: ...ts can cause blockage of the auger and to stop the operation of the pellet boiler IF PELLET BOILER IS BLOCKED THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED Using wood pellets of poor qual...

Page 10: ...t wind Chimneys Pellet boiler works constantly with a fume extractor and pressure in the flue pipes and chimney It is forbidden the flue gases to be discharged directly from the pellet boiler through...

Page 11: ...volume ensures good and smooth operation of the appliance and Pellet boiler MUST NEVER OPERATE without liquid in the heating system and under pressure less than 1 bar Failure to comply with these con...

Page 12: ...with the standard circulation pump and at the same time to keep the same level of power output and performance The pump operates on the principle of proportional pressure Technical data Max pumping 6...

Page 13: ...g the coating The flavor which is obtained as a result of the drying of the paint disappears after a few hours Ventilate the room where is located the pellet boiler If as a result of overheating or du...

Page 14: ...he icon would start the screw conveyor for 10 seconds When this time is over the screw conveyor stops again and waits until a new icon click is done The icon would only be visible in Ready Mode wherea...

Page 15: ...re one can set the Upper Buffer Bumper Sensor and the Lower Buffer Bumper Sensor operation temperature hermostat The Indoor Sensor can be either switched on or off Note It is possible that this settin...

Page 16: ...three options The first one is Switch the Timer ON If set active the fireplace would automatically transfer to Timer Mode The second one is Delayed Start To set this one active it is important that th...

Page 17: ...rst level is Installer The second level is Service Technician The third level is Delete Errors with a password 7777 The fourth password is 2468 and serves to unlock the display The display can be lock...

Page 18: ...erature On Here one can set the Water Temperature which the pump switches on at 45 0 C Hysteresis 2 C 10 C This is the thermal lag at which the pump will stop operating I e if it has been set ot switc...

Page 19: ...is way one can calculate the amount of pellets after which there should follow a cleaning process 1800 sec Fan 100 How long an Interim Purge will last The time is set within the range of 2 to 100 seco...

Page 20: ...chamber If necessary the cleaning time and power output can be adjusted in menu Cleaning When the time is over the device transfers to Fuel Mode In this mode there is a countdown as well The screw co...

Page 21: ...t one is for the Time Clock which has been preset to 600 seconds to run out and only after that the water heater temperature is checked to have decreased down below the preset one these two events hav...

Page 22: ...ition system Clean and check the electronic control system Check all electrical cables Clean the pellet fuel hopper and check auger to loosen the screw and the gear motor Check and if needed replace t...

Page 23: ...e has to drop below this value Unsuccessful Ignition Failed ignition The alarm is shown if during operation of the stove the fume outlet sensor detects lower than the set temperature When the alarm is...

Page 24: ...on manual What is needed to prepare and do before installing the pellet boiler Chimney with a diameter of at least 100 mm Opening for fresh air with a cross section not less than 80 cm 2 1 1 4 connect...

Page 25: ...ure in the heating system is reached The installer must make the appropriate setting How often should you clean the combustion chamber Before each ignition of the pellet boiler but only when it is tur...

Page 26: ...05 2020 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC 40C 26...

Page 27: ...allowed penetration of foreign substances in the firebox or hopper Do not use combustible materials to clean soot in the chimney Turn off the pellet boiler from the grid circuit before cleaning or ser...

Page 28: ...hot water outlet 9 Electronic control system set 10 Control panel 11 Circulation pump WITA DELTA MIDI 60 32 180 12 Glass 4 x 100 x 100 mm 13 Combustion chamber retort set 192 00 14 00 14 Handle 15 Fir...

Page 29: ...g population For other countries please contact you dealer Any warranty repair of the pellet boiler is recorded in the diary of warranty Warranty of the pellet boiler is NOT VALID in the following cas...

Page 30: ...05 2020 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC 40C 30 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Page 31: ...05 2020 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC 40C 31...

Page 32: ...NUAL for installation and operation of pellet boiler CLASSIC 40C 32 Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info...

Reviews: