05.2020
INSTRUCTION MANUAL
for installation and operation of pellet boiler
CLASSIC 40C
23
Do not unplug the pellet boiler from the main electrical supply during process shutdown!
Occurring an alarm event, there is the Alarm Icon
showing on the Main Screen.
On pressing the icon, you are redirected to Alarm Menu, where the alarms are listed by hour and type in descending order.
In the Alarm Menu there can display up to 6 alarms during the operation of the system.
The sound signal would stop on entering the Alarm Menu!
On the right the hour and date of alarm event displays.
On clicking the particular alarm on the left the alarms,
occurred on the particular date and hour, are visualized.
The password to delete the alarms is
7777
. Its first enter
would delete the alarms on the right, the second try
would delete the alarms on the left.
Pressure Switch
The Faulty Pressure Switch Icon is It will get active, if the
pressure switch reports too low or too high level for a
period of 60 seconds! On trigering of the alert, the device
would switch to Blocked Mode and would wait until any
human intervention fixes the problem.
In Ready Mode this alert cannot be set active!
Exhaust gases
High temperature of the combustion
chamber (above600°С)
To remove the alarm the temperature has to drop below
this value.
Unsuccessful
Ignition
Failed ignition
The alarm is shown if during operation of the stove, the
fume outlet sensor detects lower than the set
temperature. When the alarm is triggered stove shifts to
cleaning and stand-by mode.
Boiler High
Temperature
High temperature of the integral
boiler
The alarm is shown when the temperature of the integral
boiler reaches 90 degree.
Water Jacket
Sensor
Faulty integral boiler sensor
The alarm is shown when there is a fault in the sensor
"Integral boiler" or when temperature of 85° is reached
on the hopper housing
Interrupted
Supply
Restarted controller
No fire
Extinguished fire
The alarm is shown if there is no fire during second
ignition attempt and no pellets. When the alarm is
triggered stove shifts to cleaning and stand-by mode..
Damaged Fan
Fan malfunction
The alarm is shown when the rpm sensor does not receive
signal from the fan for 20 seconds.
No Pellets
No Pellets
Activated timer
The red one shows that the time has been set active and
is waiting to stop at a certain hour
Activated timer
The green one shows that the timer has been set active
and is waiting for the fireplace to start.
Indoor
Temperature
Only when room thermostat is available.
Clogged
Chimney
The alarm is triggered when the fire door is opened or the
chimney is clogged or the ashtray is opened.
t2 Problem
Problem with the thermo couple for the outlet gases.
Problem with the thermo couple for the outlet gases.