5.7 Autoscripting
Autoscripting runs BERT and Throughput test profiles in succession. Profiles are configured from the test application or ReVeal
software.
Autoscripting - BERT Setup
Autoscripting Setup
File Prefix:
Prefix added to name of test results. The default prefix is "Autoscript."
If Alarm/Error detected:
Choose to
Continue
or
Exit
testing if an alarm/error is detected.
Profile:
Select Default, Last Configuration, or None.
Testing duration can be set for seconds, minutes, hours, or days.
Tap on
View Setup
to view test setup parameters. Setup cannot be configured from this menu.
Tap on the green
Start
button to begin Autoscripting.
The soft LED light indicates the status of finished tests:
Green:
No error or alarm was detected.
Red:
An error or alarm was detected.
Starting the test brings up the BERT/Throughput Results tab. Test status is displayed in green on the bottom of the screen. When
testing finishes, results are automatically saved. Refer to
File Management
in the
TX300S, MTTplus, RXT-1200, or UX400
platform manuals
for information on accessing saved results.
Autoscripting - BERT Results
Autoscripting - Saving Results