5.0 Ethernet
Test mode, test port(s), and network settings are required prior to performing any measurements or applications
5.1 Ethernet Setup
5.1.1 Test Port Selection
Test mode, test port(s), and network settings are required prior to performing any measurements or applications.
Ethernet test modes are accessed by selecting the Test Application button at the top of the screen
. Tap on a technology
group then select a test interface. Depending on interface options purchased, the following selections are possible:
Single/dual port combinations present on RXT-6400:
Single port 400GE (OSFP)
Single port 400GE (QSFP-DD)
Single port 100GE (QSFP28)
Single port 40G, 50G (QSFP+)
Single port 25GE (SFP28)
Single port 10GE, 1GE (QSF+)
Dual port, OTN and other protocols are planned for upcoming software releases, please keep the test set software up to date.
Test Mode Selection RXT-6400
After selecting the test interface click
OK
.
The configuration parameters (header, bandwidth, etc. for each application (on each of the ports) are completely
independent from one another. All test feature combinations are allowed and completely independent (Loopback,
BERT, Throughput, RFC2544,VSAM) in dual port operation. However, some advanced tools, such as IPTV, VLAN
scan, Packet Capture, etc. are available in single port testing mode only. The user interface will provide an error
message when a feature is not available in dual port operation.
When the soft LEDs are steady green, this indicates that the module is ready to perform different tests. This may require turning the
LASER On
button for optical interfaces or tapping the
History
tab to clear blinking LED reminders of past Errors and Alarms (test
results are not affected).
RXT-6400_Module_Manual
Page 11 of 119