Stream #:
Select a stream number to configure.
Traffic Flow:
Select from Constant, Ramp, Burst, or Single Burst traffic flow.
Frame Size (Type):
Fixed or Uniform. If uniform is chosen, the user will have to input a minimum and maximum frame size.
Frame Size (bytes):
If a fixed frame size is chosen, this option is enabled. Enter the frame size when a Layer 2 or 3 is
selected. Frame sizes can be from 64bytes to 1518bytes, in addition to jumbo frames up to 10k bytes.
BW (Transmit Bandwidth):
Configure the transmit rate for the stream.
The bandwidth allocation per stream is already configured in the
General Settings
tab, but can be modified in this screen
as well.
For more information on Traffic Settings, please see
.
Throughput Setup - Traffic Setup - Constant Traffic Flow
5.6.1.4 Error Injection Settings (Per Stream Configuration)
Error injection can be performed during test. The type of errors and error injection are configured in the Error Injection tab. Once the
test is running, error injection can be performed by pressing the
Error Inject
button on the right side of the screen.
Stream #:
Select the stream to configure.
Error type:
Select from CRC, IP Checksum (Layer 3, 4 only), TCP/UDP Checksum (Layer 4 only), Sync Header Error, Block
Type Error, Pause, or Bit. With Pause selected, the unit will transmit a pause frame when the
Error Injection
icon is pressed.
The Pause time duration is configurable in units of 512 bit time. At Gigabit Ethernet speed, this is equivalent to 512 ns. For
example, if pause time is set to 1000, the pause duration will be set to 1000x512 ns.
Injection Flow:
The error injection flow determines how the selected errors will be injected. The user can select a single
error, a specific count, or rate.
Count
and
Rate:
The user will be able to configure the error count via numeric keypad.
Throughput Test - Error Injection Settings per Stream
RXT-6400_Module_Manual