5.6.1.5 Alarm Injection Settings
Alarm injection can be performed during the test. The type of alarms and alarm injection are configured in the Alarm Injection tab.
Once the test is running, alarm injection can be performed by pressing the
Alarm Inject
button on the right side of the screen.
Alarm Injection is available only with 10GE Port Tests.
Alarm Type:
Local Fault, Remote Fault, PCS-HI-BER, PCS-LOBL
Alarm Flow:
The alarm flow determines how the selected alarms will be injected. A specific Count or Continue (continuous)
can be selected.
Alarm Length:
1s, 10s, or 100s.
Throughput Alarm Injection Setup
5.6.1.6 Summary
The summary screen lists the source, destination and VLAN information of each stream. Tap on the appropriate box of each tab to
reconfigure the source, destination, or VLAN information if desired.
Throughput Test - Summary (MAC List)
Throughput Test - Summary (IP List)