BERT Setup - VLAN Tag configuration (Layer 3)
MPLS Tab:
In the MPLS tab the following parameters are configured:
MPLS label:
Configurable in the range 16 through 1,048,575 (labels 0 to 15 are reserved).
(Composed of 20 bits which allows for the creation of over one million labels).
CoS:
Configurable in the range 0 to 6.
(This field is three bits in length and maps directly to IP Precedence TOS bits to provide Class of Service (COS)).
S-bit:
Configurable 0 or 1.
(The S field is one bit in length and is used for stacking labels. This is important as it is used to indicate the last label in
the label stack).
TTL:
Configurable in the range 0 to 255. The default setting is 128 hops.
(Used to decrement the time-to-live counter).
BERT Setup - MPLS label configuration
RXT-6400_Module_Manual
Page 24 of 119