This overview field is only available for the Master Instrument.
Here are the Warning / Alarm conditions for all instruments listed
which have such conditions set.
The specifications of the output side for all components of the
Configuration: Master, Satellites and Displays is equivalent,
excepting only few differences. In the In/Out characteristics dialog
it is possible to define individual Warnings and Alarms for each
Sensor. After assigning a
Priority
, the selection of the preferred
Symbol
, the Warning and Alarm
Threshold
shall be defined.
When these min/max values are passed, Warning / Alert shall be
triggered.
Delay specifies the time to wait
after the event occurred until the
Warning / Alarm is made visible.
By use of the
Algorithm
the Threshold value is defined as upper/lower limit. The
value in the
Hysteresis
field specifies the difference value after which the Warning /
Alarm can be vanished.
June 2009
Training WinGauge Software
page 42