Configuration with web browser
49
VideoJet 400
If a floodlight activated by an alarm is to remain switched on at the
end of the alarm, select
Bistable
. If a siren triggered by an alarm is
to sound for a period of 10 seconds, select
Monostable 10s
.
Relay follows:
If necessary, select a particular event which is to trigger the relay.
The following events are possible as triggers:
z
Motion alarm
: Triggering by motion alarm
z
Input pin
: Triggering by external alarm sensor
z
Video loss
: Triggering by video signal alarm
z
Connection
: Triggering at each connection set-up
z
Remote input pin
: Triggering by switching contact of the remote
station
z
None
: No relay triggering by events
Relay name:
Assign a relay name to each relay output here.
Relay Operation
Trigger relay:
Use the button
Relay
to switch the relay by hand (e.g. for test pur-
poses or to actuate a door opener).