67
VideoJet 400
Care and Service
7
Firmware upload via FTP
The
VideoJet 400
is designed in such a way that its functions
and parameters can be updated with firmware. In such cases,
transmit the updated firmware package via the network to the
device. On termination of the connection, the firmware will be auto-
matically installed. This allows a device to be remotely serviced and
updated without a technician having to modify the device installa-
tion on site.
The latest firmware can be obtained from your VCS Service centre.
You can carry out the software upload using the FTP protocol, e.g.
with the FTP command which forms part of the standard scope of
supply of Windows 95.
)
Save the update file to your hard disk.
)
Open the MS-DOS input window.
)
Start the FTP session by entering the IP address of the
VideoJet
at the command
c:\ftp
. The FTP server of the
VideoJet
replies and waits for the input of a user name.
)
Enter the user name
Service
.
)
Then enter the Service password, if necessary. The FTP server
confirms the login.
)
Start the firmware upload by entering the name of the update file
after the command
put
.
Attention!
Before starting the firmware upload, ensure that you have selected
the correct upload file! An upload of other files can result in the
device being no longer addressable and having to be replaced.