Configuration with web browser
48
VideoJet 400
Relays settings
You can configure the switching behaviour of the relay outputs. You
can assign the relays the function of an NC contact (closed at zero
current) or an NO contact (open at zero current).
Furthermore you can specify for each output whether the output
reaction is to be bistable or monostable. In bistable mode, the trig-
gered status of the relay is maintained. In monostable mode, you
can set the time after which the relay is to return to its non-activated
state.
You can select various events for the output which automatically
activate the output. It is thus possible, for example, to switch on a
floodlight when a motion alarm is triggered and to switch off the
floodlight again at the end of the alarm.
Relay action
Idle state:
Select
Open
if the relay is to function as an NO contact or
Closed
if the relay is to function as an NC contact.
Operating mode:
Select an operating mode for the relay.