V-301Series Operating Instructions 3.02E
19
The sealing area is constructed with parts illustrated in the diagram below.
When replacing the parts, be careful to arrange the parts in the same exact order.
Replace parts according the following directions in order to maintain your machine in optimum operating
condition.
10 Replacing he routine maintenance parts
Construction of the sealing section
V-301
V-301-10DK
Pressure lever
Fluoro glass sheet
Glass tape (25mm)
Sarcon sheet
Ribbon heating element
Glass tape (13mm)
Silicone rubber
Pressure lever
Silicone rubber
Fluoro glass sheet
Glass tape (25mm)
Sarcon sheet
Braided or ribbon heating element
Braided or ribbon heating element
Glass tape (13mm)
Glass tape (13mm)
Always unplug the power plug from the wall outlet before
conducting any maintenance.
Warning
Always unplug the power plug before replacing any parts. There is a danger of electrocution, if
conducted with the plug still inserted
Warning
Do not replace parts according to other methods not described in the operating instructions.
Otherwise electrocution or burns may occur.
Warning
:KHQUHSODFLQJSDUWVDOZD\VXVHRQO\VSHFLILHGSDUWVVROGWKURXJK)8-,,038/6(2WKHUZLVH
malfunction may occur.