Adjust vacuum time
Turn the vacuum timer dial. Turn clockwise (to larger
scale) and vacuum time becomes longer.
[Dial 1 ~ 9 = about 0.1 ~ 20 seconds/
Manual =continuous operation mode.]
Set vacuum time according to a pouch size and desired
level of vacuum.
Heating and vacuum time is set by turning dials on the
control panel. Set values vary according to bag (film)
material, thickness, and size etc., therefore adjust and
set each time after changing films.
■
Adjust heating time
Turn the heating timer dial. Turn it clockwise (to the
direction of larger scales) to make heating time longer.
[Dial 1 ~ 10 = about 0.1 ~ 2.3 seconds.]
Set at the lowest temperature necessary for sealing.
Production will increase and unnecessary wear of parts
will be kept at a minimum.
8-5 Adjust sealing conditions
Warning
If you do not take enough cooling process
as described “8-11 Allow sufficient cooling
”, and set a long heating time in continuous
sealing work, there is a possibility of fire.
Attention
If vacuum timer is set to manual position,
buzzer sound "beep" one time (when
manual is reset, sounds two times), and it
means limitless time setting. Vacuum
process continues (vacuum pump
activates) until "Nozzle IN/OUT" button is
pushed.
Attention
When a braided heating element is
replaced with a ribbon heating element
and vice versa, seal finish may be different
even with the same amount of heat time.
Adjust heat time again to seal the pouch in
optimum conditions.