V-301Series Operating Instructions 3.02E
22
1
Remove the 13mm-width glass tape adhered on
the heating element.
2
Loosen the screw B of both electrodes with a
Philips screwdriver, and remove the terminal
covers. (No need to remove the terminal
covers.)
3
Insert a Philips screwdriver into the hole of the
electrode cover and loosen screw C. The heating
element can be removed.
4
When mounting a heating element, insert each
terminal between the electrode plate and
electrode plate spring. While pushing down the
terminal with your fingers so it stays in place,
tighten screw C with a Philips screwdriver.
5
Tighten the screw B loosened at the procedure 2
so the heating element is stretched tight. When
the screw B is not tightened enough, the heating
element will not be stretched tight enough,
which may result in damaging the heating
element.
6
Adhere a strip of new 13mm-width glass tape
on the heating element.
Ɣ 8SSHUKHDWLQJHOHPHQWUHSODFHPHQW
(for V-301-10DK)
Screw B
Turn
Braided heating element
Push and turn the screw with
a Philips screwdriver.
Screw C
Braided heating element
Glass tape (13mm)
Adhered on the
heating element.
The above illustration shows ribbon
heating element. The replacement
procedure is the same as for the
braided heating element.
Attention
Caution
Without loosening the screw B, the
heating element will be kept
stretched tight. Thus the heating
element terminal cannot be inserted
between the electrode plate and
plate spring.
Attention
A braided heating element is mounted to
the V-301-DK at the time of factory
shipment. The braided and ribbon heating
elements are interchangeable.
Only the ribbon heating element is used for
V-301.
Attention
When a braided heating element is
replaced with a ribbon heating element
and vice versa, seal finish may be different
even with the same amount of heat time.
Adjust heat time again to seal the pouch in
optimum conditions.