24-hour s358 (0)40 837 1150 • Email: [email protected]
connections vacon
z
36
4
Table 7: Selection of Preset Speeds
PS4
(Bit 4)
PS3
(Bit 3)
PS2
(Bit 2)
PS1
(Bit 1)
Speed Selected
0
0
0
0
Normal reference
speed as defined by
parameters
and
0
0
0
1
Preset frequency F1
0
0
1
0
Preset frequency F2
0
0
1
1
Preset frequency F3
0
1
0
0
Preset frequency F4
0
1
0
1
Preset frequency F5
0
1
1
0
Preset frequency F6
0
1
1
1
Preset frequency F7
1
0
0
0
Preset frequency F8
1
0
0
1
Preset frequency F9
1
0
1
0
Preset frequency F10
1
0
1
1
Preset frequency F11
1
1
0
0
Preset frequency F12
1
1
0
1
Preset frequency F13
1
1
1
0
Preset frequency F14
1
1
1
1
Preset frequency F15
Figure 11: Connections for Preset Speeds
PS1
PS2
PS3
PS4
Dcom
+24V
MOL
DI5
DI4
DI3
DI2
DI1
R/J
REV
FWD
Summary of Contents for 500X