24-hour s358 (0)40 837 1150 • Email: [email protected]
receiving and installation vacon
z
24
3
3.3 Dissipation Requirements
3.4 Cover Assembly and Torque Specifications
Figure 6 shows the locations of the Vacon 500x cover screws. The torque range for the Size 1 cover is 18-
26 in/lbs.
Figure 6: Vacon 500x Cover Assembly and Screw Locations
Torque specifications for control terminals and power terminals are listed in
on page 27 .
3.5 Serial Number Label
VACON Plc warrants all AC drives for three years from date of manufacture, or two years from the date of
installation, whichever comes first. For a more detailed description of VACON Plc warranty policy, see the
inside front cover of this manual, or visit the web site at
http://www.vacon.com
. To determine if your drive
is within the warranty time frame, find the bar code label or look in the lower left of the technical
nameplate. The serial number can be broken down as follows:
Model
Required Dissipation for Models Entirely Inside an Enclosure at Rated
Current, 3KHz Carrier Frequency (Watts)
0009 5
91
0012 5
114
0016 5
155
0023 5
304
0031 5
393
0037 5
459
0043 5
458
0061 5
695
0071 5
834
0086 5
776
0105 5
988
0140 5
1638
0168 5
1656
0205 5
1891
0240 5
2302
Cover screw locations
Cover screw locations
Summary of Contents for 500X
Page 1: ...vacon 500x ac drives user s manual ...
Page 13: ...24 hour support 358 0 40 837 1150 Email vacon vacon com introduction vacon z 12 1 ...
Page 117: ...24 hour support 358 0 40 837 1150 Email vacon vacon com troubleshooting vacon z 116 8 ...
Page 119: ...24 hour support 358 0 40 837 1150 Email vacon vacon com vacon 500x ultraflex options vacon 9 ...
Page 123: ......