D292105.7b.fm
Configure HMI Settings
Chapter 4: Setup
4- 17
6.
ENABLE
LEADER
.
a.
Select
Leader State
and enter
Leader Length
in millimeters
if enabled.
Note:
If
Leader
is
disabled
or a leader value of
zero
is entered, the
Taper
will
automatically advance the last part until it reaches the cut point. If a leader value
is entered, it will move the last placed part that distance beyond the cut point.
b.
Press the right
Arrow
key to move to the next screen.
Step 6:
Setup HMI
TAPER