5-28
TM-403 User’s Guide
Configure Inspection
D292105.16c.fm
Configure Keyence Monitor
Monitor Display: Menu OFF
1.
Title
: Displays the device name, the program number and the program name.
2.
Tool name:
Displays the tool number and the tool name of the tool selected. The
selected tool can be switched.
3.
Brightness correction range:
When Brightness correction is set, the range will
be displayed with a blue frame.
4.
Tool window:
Displays the tool window which has been set.
5.
Search Window:
If the search window of the tool is set, the range will be
displayed with a light blue frame.
6.
MENU/OFF button:
Changes the screen from Menu ON to Menu OFF.
7.
Status gauge
: Displays the result (OK/NG) of the tool selected.
9.
OK/NG display:
Displays the total status result.
10.
Processing time:
Displays the time from receiving a trigger until the result is
output.
11.
Image Type display:
Displays the situation of the screen. Run mode or Test
mode.
Step 2:
Vision
Setup
CONFIGURE
MONITOR