Keyence FS-N11CP & FSN12CP Sensor Amplifiers
D291842.11.fm
A-3
Appendix A: Sensors
3.
The
CV Indicator
will return to its normal display after 5 seconds have elapsed.
Locking the Keys
It is sometimes desirable to lock the keys of the sensor amplifiers so that the currents settings are
not inadvertently changed.
1.
Hold down the
Manual
button and the
Mode
button simultaneously for at least three sec-
onds.
2.
The
CV indicator
will display
Loc
to indicate that the lock is in place.
3.
Repeat the same procedure to unlock the keys. The display will flash the message
unL
.
Two-point Calibration
1.
With an obstructing object between the sensors (ideally, a full reel of cover tape), press
and release the
SET
button. The
PV Indicator
will be lit.
2.
Remove the obstruction between the sensors and press
SET
again. The amplifier will
return to its normal operating mode. The number shown on the
PV Indicator
should
change.
3.
If the sensor is in dark-ON mode, the operation indicator should be lit while there is an
obstruction between the sensors. If the sensor is in light-ON mode, the operation indica-
tor should be lit while there is no obstruction between the sensors.