3-26
TM-403 User’s Guide
Bowl Tab
D292105.6a.fm
2.
Bowl Screen 2
allows the user to set timers and delays..
A.
Press any tab in the
Tab Menu
to open that tab window.
B. Bowl
On Delay
is used to set the length of time in seconds between when the
Track Full Sensor
detects that there are no parts in the track and when the bowl is
turned on to feed parts. The minimum recommended setting for
Bowl
On Delay
is
one second.
Bowl Off Delay
is used to set the length of time in seconds between when the
Track Full Sensor
first
detects a part in the nest and when the bowl is automati-
cally turned off.
The
Linear Track’s Nest
has a sensor which detects when parts are present. The
Empty Nest Timer
setting is the time in milliseconds the
Empty Nest Timer
should wait before it beeps to indicate parts are not loading in the nest.
Track Off Delay
is the time in seconds that the vibratory will continue to vibrate
the track after the machine is stopped.
Note:
The TM-402 will use these settings for the current job. To save
Bowl Feeder Set-
tings
for future jobs, go to the
Job Tab,
select a job name and
Save
.
A
B
C
Bowl Screen 2