45
The “Gallons” function is not used in the system and the data shown on the valve
parameters is not actual. This valve regenerates on a timed frequency and does
not use water usage (gallons).
SETTINGS This function is to enter the basic set up infor-
mation required at the time of installation.
MANUAL
REGEN
This function is to initiate an immediate or
delayed manual regeneration.
DOWN /
UP
Increase or decrease the value of the set-
tings while in the programming mode.
DELAYED BACKWASH
Press and release the MANUAL REGEN.
Button to set a delayed regeneration that will
occur at the regeneration time. The main dis-
play page will show DELAYED REGEN ON.
To cancel press and release the MANUAL
REGEN. Button. The main display page will
show DELAYED REGEN OFF.
IMMEDIATE BACKWASH
To start an immediate regeneration (or step
valve through each position), press and hold
the MANUAL REGEN. Button for 3 seconds
(until beeps). The valve will start an immedi-
ate regeneration. Press any key to skip to
the next cycle.
Fusion Carbon Superfilter Key Pad Configuration
Manual Backwash Initiation
Installation, Operation and Maintenance Manual
385-GWU-1000, 385-GWU-1500, 385-GWU-2000