WARNING! Be sure the peroxide injection pump is adjusted properly before bringing the
GreenWave tank into service. Iron or other contaminants that are removed by the perox-
ide injection system can damage the GreenWave media. It is crucial that the peroxide
system is operating properly.
GreenWave Tank Startup Instructions
Installation, Operation and Maintenance Manual
385-GWU-1000, 385-GWU-1500, 385-GWU-2000
1. The GreenWave tank should be in “bypass” - shown below.
2. Open a spigot downstream of the system and slowly open both bypass valves on the
GreenWave tank. Just slightly open the valves at first and let the air start to purge from that
tank.
WARNING! Do not open the valves completely until the air is purged from the Green-
Wave tank or damage could occur.
3. Run the water for several minutes or until clear and the air has been purged from the
GreenWave tank and the entire system. Then fully open the bypass valves on the Green-
Wave tank.
4. Confirm that there are no leaks and plug the US Water UV light into the 110v GFI outlet.
5. The system is now operational and the startup is complete.