GreenWave Tank Installation Instructions
1. Place the GreenWave tanks in the desired location
on a flat level surface.
2. Make sure that the tank head is tightened securely
by hand tightening—Do Not Use a Wrench. Hand-
tight is recommended.
3.
Connect the outlet of the 5 Micron sediment filter to
the upflow inlet of the GreenWave tank.
NOTE: Put
the GreenWave tank in the bypass position (see
below). The GreenWave tank operates in the
UPFLOW mode which is opposite of most water
softeners. Therefore, the inlet is labeled
upflow
inlet
and the
outlet
is labeled
downflow inlet
. Be
sure to plumb the outlet plumbing from the 5 Micron
sediment filter to the “UPFLOW” inlet.
4.
Connect the outlet (marked “DOWNFLOW” inlet)
plumbing from the GreenWave tank to the inlet on
the 1 micron sediment filter.
Service
Position
down-flow tank
As shipped, the bypass is set-up for
down-flow use. The arrow shape of
the handles points in the wrong
direction for UP-flow use. To convert
it to UP-flow use, pull up on the red
handles until they come off. Rotate
the handle 180° and put it back on
the valve stem.
Service
Position
UP-flow tank
Bypass
Position
UP-flow tank