20
2. Lubricate the distributor O-ring and the tank O-ring. Then install the upper basket (may
look different than the pictures below) on the bottom of the valve by lining up the tabs then
turning the basket clockwise to lock it in place. Place the upper basket over the distributor
tube and push the valve on the tank. Thread the valve on the tank by turning it clockwise.
Be sure not to cross-thread the valve on the tank. Tighten the valve hand tight, then snug it
further by tapping it with the palm of the hand. DO NOT use tools to tighten the valve or
damage could occur. Move the carbon unit to the side and start the injection panel installa-
tion
Superfilter Tank and Control Valve Preparation
Installation, Operation and Maintenance Manual
385-GWU-1000, 385-GWU-1500, 385-GWU-2000