Page 1: ...User manual Bongartz GmbH purway Crystal Group Damaschkestr 10 28307 Bremen Telephone 49 0 4721 66 30 50 E Mail info purway de ...

Page 2: ...he most efficient and practical water treatment systems currently available on the market To maximize the performance of the machine please read the complete user manual before first use Please pay attention to our recommendations for the correct installation and proper maintenance If you have any questions about the product during installation or operation or if you need any assistance you can co...

Page 3: ...th caustic or corrosive materials The maximum inlet water temperature is 45 C The minimum inlet water temperature is 4 C Only use the device in closed rooms Do not expose the device to direct sunlight Only connect the device to a voltage source of maximum 230 V AC Always pull out the power plug as soon as you change the filter or carry out maintenance Do not damage the plug or the electrical suppl...

Page 4: ...3 activated carbon post filter Improves the taste of the water and keeps it fresh Brushless booster pump 800 GPD Increases the pressure in the membrane housing to overcome the osmotic pressure Combination valve Controls the concentrate flow rate during operation and flush modes Low pressure switch LPT The booster pump switches off automatically when the flow pressure falls below the minimum High p...

Page 5: ...00 GPD Wastewater ratio ca 1 1 Installation dimensions 50 x 37 x 22 cm HxWxD Weight electrical device 11 5 kg Dimensions electrical device 48 x 37 x 22 cm HxWxD Work The system is in production mode Flush The flushing is carried out Full The system is filled and ready for operation Lack Low pressure switch has detected an inlet pressure that is too low Check The device is switched off due to overh...

Page 6: ... 1x Angle plate 1x Aquastop leak sensor with two tablets 2x L adapter 3 8 tube Installation instructions Please read the operating instructions carefully and be sure to follow the instructions and information If the device or its components are damaged please contact the supplier or a specialist We are not liable for any damage caused by improper handling Make sure that the installation site is ti...

Page 7: ...clip Push the tube over a constriction seal into the connector approx 8mm Push the front ring towards the connector with your thumb and index finger Pull the tube out a little and attach the blue safety clip Carefully pull out the tube 3 Connection diagram 1 4 3 8 1 4 Water inlet Pure water Waste water ...

Page 8: ...e thread of the ball valve and screw it into the 3 way inlet valve 5 2 Take the 3 8 tube and carefully cut it to the desired length with the cutter Make sure that you do not squeeze the tube end when cutting because it can lead to leaks 5 3 Guide the union nut over one end of the 3 8 tube push the tube over the broadening on the ball valve and fasten the union nut Ball valve Screw nut Connection f...

Page 9: ...the black washer onto the threaded rod and secure the fitting by hand tightening the wing screw 6 5 Push the tube adapter onto the tube connector to the end and pull it out a little to secure it 6 6 Finally insert the tube into the tube adapter and secure with the blue safety clips 7 Installation wastewater 6 1 Drill a 6 mm hole above the siphon bend 6 2 Mount the supplied drain clamp with the sea...

Page 10: ... leak sensor to the inlet of your RO unit When installing the device for the first time leave out the insert as leaks can still occur Use the insert only after the installation has been completed and when the system is leakproof after the test run 9 Installation of the reverse osmosis membrane 9 1 Remove the tube from the L adapter on the housing lid and open it with the appropriate spanner 9 2 Ta...

Page 11: ...system Maintenance and Care Regular use of your system prevents it from drying out and possible hygiene problems If you are not going to use the device for a long time please disconnect the water supply and the power plug of your reverse osmosis system You should change the filter when you have reached the maximum service life or water volume The service life of six months based on DIN standard ma...

Page 12: ... right to left PP GC BC 1 3 Check the correct seating of both O rings Moisten them with a food grade lubricant 1 4 Push the filter cartridge up and turn the filter 90 to the right until it locks 1 Installation of the T33 post filter 2 1 Loosen the quick change adapters on the T33 postfilter and disconnect them 2 2 Prepare the new cartridge by screwing the supplied L adapter into the cartridge Befo...

Page 13: ...evice is losing water pressure Check for leaks Pure water production is very low or does not flow at all Pre filter is blocked Replace the pre filter The reverse osmosis membrane is blocked Clean or replace the membrane Inlet solenoid valve does not open Replace the inlet solenoid valve The booster pump does not have enough pressure Measure the water pressure of the pump and replace it if necessar...

Page 14: ...e in closed rooms The manufacturer hereby declares that the device complies with the basic requirements and all other relevant provisions of Directive 2016 35 EC Bongartz GmbH purway Crystal Group Damaschkestr 10 28307 Bremen Telephone 49 0 4721 66 30 50 E Mail info purway de ...