4
Technical specifications
Computer control
Voltage U
N
230V AC 50 Hz/60 Hz - 24V DC
Rated power P
N
240 W
Rated power standby P
N
< 1W
Recommended water supply pressure p
Eintr
1
–
4 bar
Operating pressure p
Betr
8 bar ± 0,5 bar
Water temperature
ϑ
Eintr
4 - 45 °C
Maximum input water value TDS Q
maxEintr
≤
500 ppm
Maximum RO water production volume
≤
2100 ml/min
Flushing
Automatic and manual flushing
Protection class DIN EN 61140
Protection class II (protective insulation)
Recommended water quality
Tap water according to DIN2000
RO membrane
3013-800 800 GPD
Wastewater ratio
ca. 1:1
Installation dimensions
50 x 37 x 22 cm (HxWxD)
Weight (electrical device)
11,5 kg
Dimensions (electrical device)
48 x 37 x 22 cm (HxWxD)
Work
The system is in production mode.
Flush
The flushing is carried out.
Full
The system is filled and ready for operation
Lack
Low pressure switch has detected an inlet pressure that is too low.
Check
The device is switched off due to overheating.
Washing
Button: triggers a flushing when pressed.
TDS [ppm]
Shows the TDS value with the unit ppm (parts per million)
TIME [S]
Display of the remaining flushing time in seconds.
Washing
function:
The system flushes automatically as soon as you connect it to the power
supply.We recommend performing manual flushing via "Washing" once a week.