© Jack Sealey Limited
Original Language Version
INSTRUCTIONS FOR:
AIR FILTER/REGULATOR/LUBRICATOR UNITS
MODEL NO’S:
SA2001.V2, SA2001/F.V2
SA2001/FR.V2, SA2001/L.V2, SA2001R
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
Refer to Instruction
Manual
1. SAFETY
p
WARNING!
Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
p
WARNING!
Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.
Keep the equipment clean and maintain it in good condition (use an authorised service agent).
Replace or repair damaged parts.
Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
p
WARNING!
Ensure that the correct air pressure is maintained and not exceeded.
p
Keep air hose away from heat, oil and sharp edges. Check air hoses for wear before each use and ensure that all connections are
secure.
DO NOT
install in direct sunlight or near any other heat source.
DO NOT
direct air from the air hose at yourself, others or animals.
D
rain the air tank daily. Water in the air line will damage equipment.
When work is complete ensure that the air supply is turned off.
If in any doubt about correct installation of this equipment consult a competent engineer.
Suitable for most workshop air supply set-ups. Die-cast control heads with clear polycarbonate bowls. Regulator assembly features locking control
knob for pre-setting air pressure and large, easy-to-read pressure gauge. Filter is fitted with automatic drain tap. Lubricator includes oil/air mix
control and sight glass. Filter and Lubricator are fitted with protection bowl cage. (Model SA2001/FR.V2 and SA2001R are supplied with separate
wall brackets. SA2001.V2 has an integral bracket).
2. INTRODUCTION
SA2001.V2
SA2001/F.V2
SA2001/FR.V2
SA2001/L.V2
SA2001R
3. SPECIFICATION
Model No:
. . . . . . . . . . . . . . . . . . . .
SA2001.V2
. . . . . . .
SA2001/F.V2
. . . . . . . .
SA2001FR.V2
. . . . . . .
SA2001L.V2
. . . . . . . . .
SA2001R
Port Size: . . . . . . . . . . . . . . . . . . . . . 3/8”BSP . . . . . . . . . . 3/8”BSP. . . . . . . . . . . .3/8”BSP . . . . . . . . . . . . 3/8”BSP. . . . . . . . . . . . . . 3/8BSP
Maximum Working Pressure: . . . . . . 145psi . . . . . . . . . . . 145psi . . . . . . . . . . . . .145psi . . . . . . . . . . . . . 145psi . . . . . . . . . . . . . . . . 145psi
Maximum Airflow:
. . . . . . . . . . . . . . . 55cfm. . . . . . . . . . . . 48cfm. . . . . . . . . . . . . .70cfm . . . . . . . . . . . . . . 55cfm. . . . . . . . . . . . . . . . . 80cfm
SA2001.V2,SA2001/F.V2, Issue:2 - 08/11/16
SA2001/FR.V2,SA2001/L.V2, SA2001R