background image

 

WL100

 Manual                                                                     Page 37                                                                      Revision: 1‐14‐2019 

PRE‐INSTALLATION PROCEDURES 

 

      DANGER!

 

 

ELECTRICAL SHOCK HAZARD.  

Only qualified personnel who have read and understand this entire manual should attempt to 
install, or service this unit, failure to do so could result in death or serious injury.  DO NOT plug 
into an electrical supply until specifically instructed.  
 
Red Compressor/Heater Switch must be in the O=OFF position while the Hot 
Tank is empty.  Damage could occur within one minute and the two Hot Tank 
Overload Devices (High Safety Limit) require manual reset if heater is turned 
on with an empty Hot Tank.  
 

 

 

       WARNING!

  

ALWAYS SANITIZE BEFORE USE. 

 Sanitize before use to eliminate any potential microbiological contaminates.      

 

CAUTION!

  

DRIP TRAY DRAIN.

  

If you intend to provide a drip tray drain for your customer, be aware that 
you will be called multiple times per month to service and unclog the tubing 
leading away from the drip tray to drain.  Users will clog the drain with 
paper clips, erasers, napkins, tea bags, gum, and various other intended 
items.  Waterlogic recommends you establish a minimum of weekly visits to 
the machine for cleaning of the drip tray drain. 

Materials Needed:  

 

Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  

 

Phillips Screwdriver   

 

Temperature Gauge 

 

Water Pitcher or Container to collect water from the faucet 

 

19 Liter (5 gallon) container or drain basin 

 

Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 

 

¼” Plastic Tubing, at least 1.25 meters (4 feet) in length, and assorted ¼” quick connect 
fittings 

 

TDS Meter and Test Strips for measuring chlorine – Optional 

 

Sanitizing Cartridge – an empty Waterlogic Filter with the cartridge removed 

 

1.

 

Unpack the 

Waterlogic WL100 Water Treatment System 

and check exterior for damage.

 

 

  

 

Sanitizing 

 
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or another approved 
cleaner throughout the cold‐water circuit.  Follow all instructions on the sanitizer and flush with 
fresh water through the faucet until odor and taste is acceptable. 

 

       WARNING!  

USE PROPER PERSONAL PROTECTIVE EQUIPMENT

 

Summary of Contents for WL100

Page 1: ...rain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to the machine for cleaning of the drip tray drain Ma...

Page 2: ...ainer and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 8 or 11 Liters 2 or 3 gallons of water...

Page 3: ...he cold circuit Chlorine test strips can be used to evaluate the water 12 Once the sanitizer odor taste has been flushed out of the cold side of the machine the sanitization process for the Cold Circu...

Page 4: ...e the Heater approximately 10 minutes to heat the water from ambient 24 C 75 F to the factory set point of 85 C 185 F Dispense a cup of hot water to ensure the temperature odor taste is acceptable WAR...

Page 5: ...ncoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc from scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor...

Page 6: ...ont Panel 8 Unclip the White Red and Black wire connectors from PCB to allow Front Cover to be removed 9 Remove Front Panel 10 Disconnect tubing to allow water to drain from the WL100 Water Treatment...

Page 7: ...ater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to scalding hot water Red Compressor Heater Switch mus...

Page 8: ...e Solenoids 7 Disconnect tank line outlet lines from Hot and Cold Solenoids to drain into basin or bucket 8 Turn outlet fittings outward to avoid water spilling onto the Compressor 9 Reconnect Tubing...

Page 9: ...on CAUTION USE A WATER PRESSURE REGULATOR Waterlogic will not be responsible for injury or damage caused by excessive water pressure Operating pressure must be 40 psi to 60 psi Be aware any of potenti...

Page 10: ...must be in the O OFF position while the Hot Tank is empty Damage could occur within one minute and the overload high limit will require manual reset if Heater is turned on with an empty Hot Tank 6 Mo...

Reviews: