WL100

 Manual                                                                     Page 46                                                                      Revision: 1‐14‐2019 

 

2.

 

Check to ensure that the Red Heater and Compressor Switch is the 

O=OFF 

position.  

 

NOTE:

  Switches have internal LED that illuminates when placed in

 I=ON

 position 

 

 

3.

 

Connect the power cord to the back of the 

Waterlogic WL100 Water Treatment System 

and to a 

120 Volt supply. 

 

4.

 

Fill the Cold Tank.  Hold a container under the Dispensing Faucet, press and hold Cold (Blue) 
Dispensing button until a continuous flow of water is obtained.  Once a continuous flow is 
obtained, release the dispensing button.  Cold Tank is now full.   

 

5.

 

Fill the Hot Tank.  Hold a container under the dispensing faucet.  Press both of the Hot (Red) 
Dispensing buttons until a continuous flow of water is obtained.  Once a continuous flow is 
obtained, the Hot Tank is full.  

 

       CAUTION!  

NEVER TURN ON HEATER BEFORE FILLING HOT TANK. 

Red Heater and Compressor Switch

 

must be in the O=OFF position while the Hot 

Tank is empty.  Damage could occur within one minute and the overload (high 
limit) will require manual reset if Heater is turned on with an empty Hot Tank.  

 
 
 

6.

 

Move the 

Waterlogic WL100 Water Treatment System 

into its final operating position.  Be sure 

that a minimum of 5 cm (2 inch) clearance is maintained around both the sides and the back of 
the unit.  This is important to allow proper airflow and heat exchange of refrigeration system.  

 

7.

 

Level unit using the adjustable feet to level if necessary.  Never install on incline. 

 
 
 

8.

 

Turn the Red Heater and Compressor Switch on 

I=ON position

.   

 
 
 

9.

 

When the unit has reached its Hot Temp Set Point, the Heater will cycle off.   When the 
unit has reached its Cold Temp Set Point Temperature, the Compressor will cycle off. 

 

10.

 

Once the unit is at the target temperature(s), sample the water to ensure water meets 
expectations and additional rinsing or adjustment is not required.  

 

 

11.

 

Check the 

WL100 Water Treatment System

 for any leaks.  External Leak Protection is always 

recommended. 

 

 

Summary of Contents for WL100

Page 1: ...rain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to the machine for cleaning of the drip tray drain Ma...

Page 2: ...ainer and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 8 or 11 Liters 2 or 3 gallons of water...

Page 3: ...he cold circuit Chlorine test strips can be used to evaluate the water 12 Once the sanitizer odor taste has been flushed out of the cold side of the machine the sanitization process for the Cold Circu...

Page 4: ...e the Heater approximately 10 minutes to heat the water from ambient 24 C 75 F to the factory set point of 85 C 185 F Dispense a cup of hot water to ensure the temperature odor taste is acceptable WAR...

Page 5: ...ncoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc from scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor...

Page 6: ...ont Panel 8 Unclip the White Red and Black wire connectors from PCB to allow Front Cover to be removed 9 Remove Front Panel 10 Disconnect tubing to allow water to drain from the WL100 Water Treatment...

Page 7: ...ater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to scalding hot water Red Compressor Heater Switch mus...

Page 8: ...e Solenoids 7 Disconnect tank line outlet lines from Hot and Cold Solenoids to drain into basin or bucket 8 Turn outlet fittings outward to avoid water spilling onto the Compressor 9 Reconnect Tubing...

Page 9: ...on CAUTION USE A WATER PRESSURE REGULATOR Waterlogic will not be responsible for injury or damage caused by excessive water pressure Operating pressure must be 40 psi to 60 psi Be aware any of potenti...

Page 10: ...must be in the O OFF position while the Hot Tank is empty Damage could occur within one minute and the overload high limit will require manual reset if Heater is turned on with an empty Hot Tank 6 Mo...

Reviews: