WL100
Manual Page 46 Revision: 1‐14‐2019
2.
Check to ensure that the Red Heater and Compressor Switch is the
O=OFF
position.
NOTE:
Switches have internal LED that illuminates when placed in
I=ON
position
3.
Connect the power cord to the back of the
Waterlogic WL100 Water Treatment System
and to a
120 Volt supply.
4.
Fill the Cold Tank. Hold a container under the Dispensing Faucet, press and hold Cold (Blue)
Dispensing button until a continuous flow of water is obtained. Once a continuous flow is
obtained, release the dispensing button. Cold Tank is now full.
5.
Fill the Hot Tank. Hold a container under the dispensing faucet. Press both of the Hot (Red)
Dispensing buttons until a continuous flow of water is obtained. Once a continuous flow is
obtained, the Hot Tank is full.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Red Heater and Compressor Switch
must be in the O=OFF position while the Hot
Tank is empty. Damage could occur within one minute and the overload (high
limit) will require manual reset if Heater is turned on with an empty Hot Tank.
6.
Move the
Waterlogic WL100 Water Treatment System
into its final operating position. Be sure
that a minimum of 5 cm (2 inch) clearance is maintained around both the sides and the back of
the unit. This is important to allow proper airflow and heat exchange of refrigeration system.
7.
Level unit using the adjustable feet to level if necessary. Never install on incline.
8.
Turn the Red Heater and Compressor Switch on
I=ON position
.
9.
When the unit has reached its Hot Temp Set Point, the Heater will cycle off. When the
unit has reached its Cold Temp Set Point Temperature, the Compressor will cycle off.
10.
Once the unit is at the target temperature(s), sample the water to ensure water meets
expectations and additional rinsing or adjustment is not required.
11.
Check the
WL100 Water Treatment System
for any leaks. External Leak Protection is always
recommended.