NOTE COM.F.013 CABLE SECTION LIST
MAX LOAD
MAX LINE
LENGTH
50 m
MAX LINE
LENGTH
100 m
MAX LINE
LENGTH
150 m
MAX LINE
LENGTH
200 m
UP TO 25 mA
0.22 mm
2
0.22 mm
2
0.22 mm
2
0.22 mm
2
UP TO 45 mA
0.22 mm
2
0.22 mm
2
0.50 mm
2
0.50 mm
2
UP TO 50 mA
0.22 mm
2
0.22 mm
2
0.50 mm
2
0.75 mm
2
UP TO 60 mA
0.22 mm
2
0.50 mm
2
0.50 mm
2
0.75 mm
2
UP TO 90 mA
0.22 mm
2
0.50 mm
2
0.75 mm
2
1 mm
2
UP TO 120 mA
0.50 mm
2
0.75 mm
2
1 mm
2
1.50 mm
2
UP TO 170 mA
0.75 mm
2
1 mm
2
1.50 mm
2
2.50 mm
2
UP TO 220 mA
1 mm
2
1.50 mm
2
2.50 mm
2
4 mm
2
UP TO 250 mA
1 mm
2
2.50 mm
2
4 mm
2
4 mm
2
UP TO 300 mA
1.50 mm
2
2.50 mm
2
4 mm
2
4 mm
2
UP TO 500 mA
2.50 mm
2
4 mm
2
NOT SUGGESTED
NOT SUGGESTED
NOTE F.046:
Set N. 8 DIP SWITCH in ON position
NOTE F.064: NC connection of detector Ref.1033/0135 allow ANTI-MASKING function only if
system is ON
VX.008 – Connect the device to a filter and power line protection device.