34
DS1061-036A
5.3 FIRST
POWER-UP
At the first power-up:
•
The inputs LEDs blink in sequence
.
•
On the LCD display appears for 2 seconds the control panel firmware version
.
•
Then the LCD display starts blinking
.
At this moment perform as follows
:
•
Acquire a key (electronic or transponder) as Master key, by inserting or bring it near a reader.
Or:
•
Enter on the keypad the code that will become the Master code
(from 4 to 6
digits freely selectable
)
and confirm it by pressing the
OK
button on the keypad
.
If in the system are present both keypads and readers, to acquire a Master key or set a Master code is
indifferent.
After acquiring the Master key (or after setting the Master code), the LCD display stops blinking and shows
the first item of the main menu. Now it is possible to program the control panel (go directly to paragraph
5.4.2
Main programming menu
).
WARNING
: Write the programmed Master code, or mark the acquired Master key, because they are
necessary to access to Maintenance functions.
5.4
SYSTEM CONFIGURATION VIA HARDWARE
5.4.1
Entering in programming mode
For enter in control panel programming mode, when it has been already programmed before, follow the
instructions below
:
1.
Activate the system maintenance mode, as described in paragraph
7.1
MAINTENANCE PROCEDURE
.
2.
Keep the
OK
programming button pressed for 3 seconds.
3.
On the LCD display appears for 2 seconds the control panel firmware version
.
4.
Wait until on the LCD display appears the first item of the main programming menu
.
Now it is possible to program the control panel (go to paragraph
5.4.2
Main programming menu
).