DS1061-036A
49
How to record a message
To record a message, follow the instructions below:
1.
Connect the provided earphone with microphone to the speech synthesis card.
Figure 30 –
Connection of earphone to speech synthesis card
2.
Scroll the programming menu until the memory location for the kind of message to customize is
reached.
3.
Press
OK
button to start recording; the LCD display starts blinking.
4.
Pronounce clearly and distinctly the message to be recorded. When the available time is elapsed, the
LCD display stops blinking and
recording is interrupted.
5.
If recording is not satisfactory, it is possible to do it again, by repeating the procedure from step 3.
How to play a message
To play a message, follow the instructions below:
1.
Connect the provided earphone with microphone to the speech synthesis card.
2.
Scroll the programming menu until the memory location for the kind of message to customize is
reached.
3.
Press
OK
button to start playback.
5.4.13
Keypad auxiliary inputs programming
By default the input is configured as “contact”, for example for a magnetic contact on a door or an infrared
detector, but it can also be configured to connect a rolling shutter detector.
How to set the auxiliary input for the contact
1.
Disarm the system.
2.
Put the keypad rotary switch on “F”.
3.
Press twice the control panel “
OK
” button; a confirmation beep will be emitted.
4.
Put back again the keypad rotary switch on its original address (position “0”, “1”, “2” or “3”).
How to set the auxiliary input for the rolling shutter detector
1.
Disarm the system.
2.
Put the keypad rotary switch on “F”.
3.
Press twice the keypad “
X
” button; a confirmation beep will be emitted.
4.
Put back again the keypad rotary switch on its original address (position “0”, “1”, “2” or “3”).
5.4.14
Exit from programming procedure
To exit from the programming procedure, it is sufficient to go to the main level of menus tree, by pressing
ESC
button repeatedly and then keep
ESC
button pressed for 3 seconds. The LCD display turns off and
the parameters configured until that time will be stored in the control panel.